Click Here To Download PDF

PIE 525Plus Specifications

 

(Unless otherwise indicated all specifications are rated from a nominal 23°C, 70% RH for 1 year from calibration)

 

 

General

Source Thermocouple


 

Operating Temperature Range

 

Storage Temp. Range Relative Humidity Range

 

Temperature Drift

 

Size

 

Weight

-25 to 60 °C (-10 to 140 °F)

 

-30 to 60 °C (-22 to 140 °F)

 

10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing

 

10 % ≤RH≤ 70 % (35 to 60 °C), Non-condensing

 

± 0.01% of span outside of 23°C ±10 °C (73°C ±18 °F)

 

5.63 x 3.00 x 1.60 in, 143 x 76 x 41 mm (L x W x H)

 

12.1 ounces, 0.34 kg (including boot & batteries)

Accuracy

 

Cold Junction

Compensation Millivolt Range Output Impedance Source Current Noise

±(0.008% of Reading + 0.006 mV)

 

  • 09°F (±0.05 °C) – Thermistor traceable to NIST for 11 years

 

-13.000 to 80.000 mV

 

< 0.3 Ohms

 

> 20 mA (drives 80 mV into 10 Ohms)

 

≤ 4 microvolts p-p for frequencies of 10 Hz or below

 

 

Batteries

Four “AA” Alkaline 1.5V (LR6)

Read Thermocouple


 

Battery Life (Typical)

 

Isolation:    Voltage

 

Normal Mode Rejection Common Mode Rejection

 

Optional NiMh Rechargeable battery kit

 

Low Battery

25 Hours Thermocouple or RTD, 8 Hours milliamp

 

60V rms between all milliamp functions/Read V DC and Source V DC/Thermocouple/Ohms/RTD

 

50/60 Hz, 50 dB

 

50/60 Hz, 120 dB

 

Charger, four NiMh batteries [Part # 020-0103]

 

Low battery indication with nominal 1 hour of operation left

Accuracy

 

Cold Junction

Compensation

 

Millivolt Range

 

Input Impedance

 

Open Thermocouple

 

Threshold

 

Pulse

±(0.008% of Reading + 0.006 mV)

 

  • 09°F (±0.05 °C) – Thermistor traceable to NIST for 11 years

 

-13.000 to 80.000 mV

 

> 10 Megohms

 

18,000 Ohms nominal

 

< 10 microamp pulse for 400 milliseconds

 

 

Protection against misconnection

Over-voltage protection to 60 V dc (rated for 30 seconds)

Source Ohms & RTD


 

Display

High contrast graphic liquid crystal display. LED backlighting for use in low lit areas.

3 & 4 Wire Accuracy

 

From 1 to 10.2 mA

External Excitation Current

±(0.015% of Reading + 0.05 Ohms)

 

 

Read mA

 

Ranges and Resolution 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA
Accuracy ≤ ± (0.02 % of Reading + 0.003 mA)
Voltage burden ≤ 2V at 24 mA
Overload/Current limit 25 mA nominal
protection

 

Source mA / Power & Measure Two Wire Transmitters & PWRM LEAK

 

Ranges and Resolution 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA
Accuracy ≤ ± (0.02 % of Reading + 0.003 mA)
Loop compliance voltage ≥ 24 DCV @ 20.00mA

Below 1 mA of External Excitation Current

 

2 Wire Accuracy*

 

Resistance Ranges

 

RMS Noise

 

Allowable Excitation Current Range

 

Pulsed Excitation Current Compatibility

0.025 mV

±(0.015% of Rdg + mA Excitation Current + 0.05 Ohms)

 

Add 0.1 Ohms to 3 Wire & 4 Wire Accuracy

 

400 Ohm Range: 0.00 to 401.00 & 0.000 to 401.000

 

4000 Ohm Range: 0.0 to 4010.0 & 0.00 to 4010.00

 

400 Ohm Range: ≤ ± 0.005 Ohms from 0.1 to 10 Hz

 

4000 Ohm Range: ≤ ± 0.05 Ohms from 0.1 to 10 Hz

 

0 to 400 Ohm: 10.2 mA max; steady or pulsed/intermittent

 

401 to 4000 Ohms: 1 mA max; steady or pulsed/intermittent

 

DC to 0.01 second pulse width

 

 

Loop drive capability        1200 Ω at 20 mA

 

950 Ω with Hart Resistor or leak detection running

 

mA 2-Wire Transmitter Simulation

Read Ohms & RTD

 

3 Wire & 4 Wire Accuracy ±(0.015% of Reading + 0.05 Ohms)
2 Wire Accuracy* ±(0.015% of Reading + 0.15 Ohms)
Resistance Ranges Same as Source Ohms & RTD

 

 

Accuracy

 

Voltage burden

 

Overload/Current limit protection

 

Loop voltage limits

 

Same as Source/Power & Measure

 

  • 2V at 20 mA

 

24 mA nominal

 

2 to 60 VDC (fuse-less protected from reverse polarity connections)

 

Excitation Current            0.9 mA to 401 Ohms, 0.4 mA to 4010 Ohms (nominal)

 

* 2 Wire specifications do not include resistance of the lead wires

Additional information

Weight 1 lbs