Catalog Number | Description | Voltage |
FTC3/05 | TC-3000, 20×0.5ml Thermal Cycler | 120/240 |
FTC3/02 | TC-3000, 25×0.2mL Thermal Cycler | 120/240 |
Accessories | ||
FTC3/05/B | 20 x 0.5mL block | Block |
FTC3/02/B | 25 x 0.2mL block | Block |
TC-3000 Features & Benefits
- One of smallest footprints on the market
- Fast ramping
- Unparalleled block uniformity
- Low cost
- PC Control and networking
- Alpha-numeric screen, keypad and program naming
- Fast and intuitive programming with large memory
- Ready-to-go templates
- Interchangeable blocks
- Two models available:
25 x 0.2ml and 20 x 0.5ml microtubes
The TC-3000 Thermal Cycler is unrivalled as a reliable low cost personalcycler. Designed for research and teaching, the TC-3000 offers the ultimate in low cost solutions where ease of use is high on the priority list. It has numerous applications in Molecular Biology and Diagnostic laboratories and is suitable for use with diagnostic kits.
It has been designed for the individual; priced to be inexpensive enough so anyone can own one. The TC-3000’s high speed allows a typical 30 cycle program to be completed in around 1 hour, enabling the operator to complete more work in a day.
Using advanced peltier technology, the TC-3000 is capable of heating/cooling rates better than 2.0 – 3.0°
C/second (average cooling and heating) and using a high tolerance thermistor sensor to give a temperature stability of ±
0.1°
C and a block uniformity of ±
0.5°
C.
One of TC-3000’s many features is incremental/decremental segment hold time. This allows the user to increase or decrease the hold time of a given segment hold with each cycle. Use incrementally on ‘extension’ for techniques such as Long DNA and RAPD to allow sufficient time for the increasing quantity of DNA to extend. Use decremental feature on ‘denaturation’ to allow initial highly specific denaturation and then less time with each cycle at 95°
C so as to maintain the enzyme’s (taq)half-life
TC-3000 Specifications | |
Blocks Formats | |
0.5ml capacity | 20 |
0.2ml capacity | 25 |
384-well block | – |
In-situ block | – |
User interchangeable | Yes |
Block Temperature Specifications | |
Maximum ramp rate* | 3.6°C/sec |
Block uniformity at 50°C* | <±0.1°C |
Temperature range | 4°C to 99°C |
Temperature set point precision | 0.1°C |
Heated Lid | |
Selectable heated lid temperature | 100°C – 115°C |
Heated lid enable/disable | Yes |
Over temperature cut out | Yes |
Regulated lid pressure | Yes |
Heated lid only comes on if block is set above 35°C | |
Programming | |
Number of programs # | 80 |
Password protection | Yes |
Programming | 4-line alphaN |
Graphical display | No |
Incremental/decremental temperature | Yes |
Incremental/decremental hold time | Yes |
Maximum hold time | 18 hrs |
Minimum hold time | 1 sec |
Variable programmable ramp rate | 0.1°C/sec steps |
Run end time calculation | Yes |
Pause and stop facility | Yes |
End of program alarm (enable/disable) | Yes |
Auto restart on power failure | Yes |
Miscellaneous | |
Serial port | RS232 |
Dual Voltage (120/230V) | Yes |
Temperature sensor | Thermistor |
Peltier elements/block | 4 |
Dimensions L x W x H (in inches) | 13 x 7 x 7.5 |
Footprint L x W (in inches) | 91 in2 |
Connection to PC control program | Yes |
Free software upgrades from website | Yes |
Power consumption | 230 Watts |
Frequency | 50 – 60 Hz |
Net weight | 6kg (total) |
Warranty | 4 years or 80,000 cycles-parts & labor |