Testo 330-2G Offers
For commercial and industrial boiler combustion analysis, the combustion analyzer is properly outfitted NO sensor to calculate NOX, high range CO, sensor protection, large memory for maintaining service records, and on-site printing capability. The combustion analyzer has the longest sensor warranty on the market – 4 years!. Rugged construction and high quality sensors provide years of reliability and very low cost-of-ownership.
Features
- Calculates NOX
- Over-range sensor protection
- Built-on dilution systems allows for CO readings to 30,000ppm
- On board self-diagnostics and service tracking
- Efficient “in the green” or “in the red” display results allow for fine tuning the combustion process
- Optional probes for hi-temp, gas leak, ambient CO and more
- Memory up to 500,000 readings
- Calculates CO2, efficiency, excess air, CO air free
Testo 330-2G LL Kit #2 Technical Data
Memory | 500.000 values |
Storage temperature | -20 to +50 °C |
Operating temperature | -5 to +45 °C |
Dimensions | 270 x 90 x 65 mm |
Differential Pressure |
|
---|---|
Measuring range | 0 to 300 inH2O |
Accuracy | ±0.5 inH2O (0.0 to 50.0 inH2O) ±1% of rdg. (50.1 to 100.0 inH2O) ±1.5 % of rdg. (remaining range) |
Resolution | 0.1 inH2O |
CO low |
|
Measuring range | 0 to 500 ppm |
Accuracy | ±2 ppm (0.0 to 40.0 ppm) ±5% of rdg. (remaining range) |
Resolution | 0.1 ppm |
NO measurement |
|
Measuring range | 0 to 3000 ppm |
Accuracy | ±5 ppm (0 to 100 ppm) ±5% of rdg. (101 to 2000 ppm) ±10% of rdg. (2001 to 3000 ppm) |
Resolution | 1 ppm |
O2 measurement |
|
Measuring range | 0 to 21 Vol. % |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol. % |
Exhaust Gas Measurement |
|
Measuring range | 0 to 99.9% |
Resolution | 0.1% |
Draft Measurements |
|
Measuring range | -9.99 to +40 inH2O |
Accuracy | ±0.02 inH2O or ±5% of rdg. (-0.50 to +0.60 inH2O) ±0.03 inH2O (+0.61 to +3.00 inH2O) ±1.5% of rdg. (+3.01 to +40.00 inH2O) |
Resolution | 0.01 inH2O |
CO measurement (electrochemical) |
|
Measuring range | 0 to 8000 ppm |
Accuracy | ±10 ppm or ±10% of rdg. (0 to 200 ppm) ±20 ppm or ±5% of rdg. (201 to 2000 ppm) ±10% of rdg. (2001 to 8000 ppm) |
Resolution | 1 ppm |
CO2 |
|
Measuring range | 0 to 1 Vol. % 0 to 10.000 ppm |
Accuracy | ±(50 ppm ±2% of rdg.) (0 to 5000 ppm) |
Reaction time | Approx. 35 sec. |
CO |
|
Measuring range | 0 to 500 ppm |
Accuracy | ±5 ppm (0 to 100 ppm) ±5% of rdg. (>100 ppm) |
Resolution | 1 ppm |
Reaction time | Approx. 35 sec. |
Efficiency measurement (ETA) |
|
Measuring range | 0 to 120% |
Resolution | 0.1% |
Type K |
|
Measuring range | -40 to +1200 °C |
Accuracy (relative) | ±0,5 °C (0.0 to +100.0 °C) ±0,5 % of rdg. (remaining range) |
Resolution | 0.1 °C (-40 to 999,9 °C) 1 °C (remaining range) |
CO2 – determination |
|
Measuring range | 0 to CO2 max |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol. % |
Reaction time | < 40 sec. |