Welded stainless steel Bourdon tubesreduce chance of leakage, (even in the event of fire), in Model BB DifferentialPressure Switches. Units are ideal for checking differential pressure (head)across high pressure pumps and filters. Hermetically sealed mercury wettedcontacts help ensure reliable operations. Extra sensitive (fixed deadband) unitsare available on special order, as are weatherproof and explosion-proofenclosures
EXAMPLE | BB | 523 | 2 | 6S | BB-523-2-6S Differential Pressure Control, 403 SS Bourdon tubes, adjustable deadband, automatic reset, SPST magnetic mercury switch, adjustable range 0-40 psid, operating range 5-100 psig, flanged back | ||
CONSTRUCTION | BB | General purpose enclosure, NEMA-1 (standard) | CSA | ||||
HOUSING OPTIONS | W | Weatherproof enclosure, NEMA-3S, 4, 4X | CSA | ||||
E | Explosion-proof enclosure, NEMA 7, 9 – Class I Group C & D, Class II Group E, F & G. | CSA | |||||
CIRCUIT (SWITCHING) OPTIONS | 2_ _ | 2 | SPST magnetic mercury switch, opens on differential pressure increase. Fixed deadband. Rated 0.3A at 120 VAC, 0.15A at 240 VAC | CSA | |||
2_ _ | 3 | SPST magnetic mercury switch, closes on differential pressure increase. Fixed deadband. Rated 0.3 at 120 VAC, 0.15 at 240 VAC | CSA | ||||
4_ _ | 4122 | 2 stage: 2 each SPST magnetic mercury switches, 1 each opens on differential pressure increase, 1 each opens on further increase. Rated 0.3 at 120 VAC, 0.15 at 240 VAC | CSA | ||||
4_ _ | 4129 | 2 stage: 2 each SPST magnetic mercury switches, 1 each closes on differential pressure increase, 1 each closes on further increase. Rated 0.3 at 120 VAC, 0.15 at 240 VAC | CSA | ||||
4_ _ | 4132 | 2 stage: 2 each SPST magnetic mercury switches, 1 each closes on differential pressure increase, 1 each closes on differential pressure decrease. Both open mid range. Rated 0.3 at 120 VAC, 0.15 at 240 VAC | CSA | ||||
4_ _ | 4123 | 2 stage: 2 each SPST magnetic mercury switches, 1 each opens on differential pressure increase, 1 each opens on differential pressure decrease. Both close mid range. Rated 0.3 at 120 VAC, 0.15 at 240 VAC | CSA | ||||
5_ _ | 2 | SPST magnetic mercury switch, opens on differential pressure increase. Adjustable deadband. Rated 5A at 120 VAC, 2.5A at 240 VAC, 2.5A at 120VDC, 1A at 240 VDC | CSA | ||||
5_ _ | 3 | SPST magnetic mercury switch, closes on differential pressure increase. Adjustable deadband. Rated 5A at 120 VAC, 2.5A at 240 VAC, 2.5A at 120VDC, 1A at 240 VDC | CSA | ||||
BOURDON TUBE MATERIALS | 2_ | Type 403 stainless steel Bourdon tubes | CSA | ||||
4_ | Type 316 stainless steel Bourdon tubes | CSA | |||||
MOUNTING | 3 | Flanged back | CSA | ||||
ADJUSTABLE DIFFERENTIAL PRESSURE RANGES OPERATING PRESSURE RANGES Maximum pressure not to exceed | 25S | Adjustable range 0-40 psid, operating range 30" Hg vac – 60 psig, 403SS Bourdon tube | CSA | ||||
6S | Adjustable range 0-40 psid, operating range 5-100 psig, 403SS Bourdon tube | CSA | |||||
8S | Adjustable range 0-120 psid, operating range 10-200 psig, 403SS Bourdon tube | CSA | |||||
9S | Adjustable range 0-180 psid, operating range 10-300 psig, 403SS Bourdon tube | CSA | |||||
10S | Adjustable range 0-360 psid, operating range 25-600 psig, 403SS Bourdon tube | CSA | |||||
11S | Adjustable range 0-600 psid, operating range 50-1000 psig, 403SS Bourdon tube | CSA | |||||
12S | Adjustable range 0-900 psid, operating range 100-1500 psig, 403SS Bourdon tube | CSA | |||||
13S | Adjustable range 0-1500 psid, operating range 300-2500 psig, 403SS Bourdon tube | CSA | |||||
15S | Adjustable range 0-3000 psid, operating range 500-5000 psig, 403SS Bourdon tube | CSA | |||||
16S | Adjustable range 0-5000 psid, operating range 1000-8000 psig, 403SS Bourdon tube | CSA | |||||
23E | Adjustable range 0-38 psid, operating range 5-75 psig, 316SS Bourdon tube | ||||||
6E | Adjustable range 0-36 psid, operating range 10-100 psig, 316SS Bourdon tube | ||||||
24E | Adjustable range 0-55 psid, operating range 10-150 psig, 316SS Bourdon tube | ||||||
9E | Adjustable range 0-200 psid, operating range 10-300 psig, 316SS Bourdon tube | ||||||
21E | Adjustable range 0-275 psid, operating range 30-400 psig, 316SS Bourdon tube | ||||||
22E | Adjustable range 0-450 psid, operating range 75-800 psig, 316SS Bourdon tube | ||||||
11E | Adjustable range 0-500 psid, operating range 100-1000 psig, 316SS Bourdon tube | ||||||
13E | Adjustable range 0-925 psid, operating range 200-2500 psig, 316SS Bourdon tube |