Specifications
(PDF)
| Fluke
287 |
True-rms
Electronics Logging Multimeter with TrendCapture
All models
include:
- Manual
- 6 AA Batteries, installed
- TL71 Silicone Test Leads
- Probe Holder
- Two AC72 Alligator Clips
|
Supplemental
Material:
- Registration Card
- Cal Practices Document
- CD-ROM Users' Manual (16
languages)
- Getting Started Manual
- Statement of Calibration
Practices Document
|
|

- Fast, accurate viewing of measurements with
large ¼ VGA dot matrix display
- TrendCapture graphing capability allows
logged data to be viewed on the meter, without being downloaded
- Save multiple logging sessions
- More memory-extended on-board logging
capability including multiple sessions
- 0.025 % basic dc accuracy
- 100 kHz ac bandwidth
- info button image On board help screen for
measurement functions
The Fluke 287
True-rms Electronics Logging Multimeter with TrendCapture quickly
documents design performance and graphically displays what happened.
Its’ unique logging and graphing capabilities mean you no longer need to
download logged readings to a PC to detect a trend. The Fluke 287 packs
more accuracy and convenience into a handheld multimeter than ever before,
putting more problem solving power in your hands. It is the ultimate
handheld tool for demanding applications that require high-precision.
Be sure to also
check out the Fluke 289 True-rms Industrial Logging Multimeter with
TrendCapture designed for industrial professionals.
Key Features Include:
- New with V 1.1 Upgrade! Zoom on
trend provide unprecedented ability to view analyze TrendCapture
data; see detail at X5 magnification.
- New with V 1.1 Upgrade! Simplified
Record screen when setting up recording
- New with V 1.1 Upgrade! Logging
function with expanded memory for unattended monitoring of signals
over time. Using on-board TrendCapture users can graphically
review logged readings without needing a PC. Store up to 15,000
recorded events.
- Large 50,000 count, ¼ VGA display
with white backlight. Multiple sets of measurement information can
simultaneously be displayed at the same time.
- Logging function with TrendCapture
is an essential tool for documenting the performance of your
designs, processes or systems, or unattended monitoring while you
work on other projects. It plots measurements as a single line to
help detect signal anomalies over time. Using on-board
TrendCapture, you can graphically view logged readings without a
PC. (Software and interface cable optional).
- Log multiple sessions or log data
continuously for over 200 hours.
- i-info button. On board help screens
for measurement functions. Unsure about a function? Go to that
function and Press the “i” button.
- Now, name your saved measurements
and also recall measurements made in the field
- Real Time Clock – for automatic
time stamping of saved readings
- Field upgradeable and expandable
meter lets you stay current as new capabilities are added
- Multi-lingual interface
- Min/Max/Average with Time Stamp to
record signal fluctuations
- Soft keys, scroll buttons and easy
navigation control access to secondary functions.
- 0.025% Basic DC accuracy
- 100 kHz ac bandwidth
- True-rms ac voltage and current for
accurate measurements on complex signals or non-linear loads.
- Measure up to 10A (20 A for 30
seconds; 10A continuous)
- 100 mF capacitance range
- Temperature function
- Relative mode to remove test lead
resistance from low ohms or capacitance measurements
- Peak capture to record transients as
fast as 250 μs
- Premium test leads and alligator
clips included
- Optional FlukeView forms enables you
to document, store and analyze individual readings or a series of
measurements, then convert them into professional-looking
documents
- Optional magnetic hanger allows you
to hang the meter for easy viewing while freeing your hands to
focus on the job.
- Limited lifetime warranty
- CAT III 1000 V / CAT IV 600 V safety
rated
|
| Specifications |
| Voltage
DC |
| Accuracy |
0.025 % |
| Range and
Resolution |
50.000 mV,500.00 mV,
5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Voltage
AC |
| Accuracy |
0.4 %(true-rms) |
| Range and
Resolution |
50.000 mV,500.00 mV,
5.0000 V, 50.000 V, 500.00 V, 1000.0V |
|
| Current
DC |
| Accuracy |
0.06 % |
| Range and
Resolution |
500.00 µA, 5000.0 µA,
50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Current
AC |
| Accuracy |
0.6%(true-rms) |
| Range and
Resolution |
500.00 µA, 5000.0 µA,
50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
|
| Temperature
(excluding probe) |
| Accuracy |
1.0 % |
| Range and
Resolution |
-200.0 °C to 1350.0 °C
(-328.0 °F to 2462.0 °F) |
|
| Resistance |
| Accuracy |
0.05 % |
| Range and
Resolution |
500.00 Ω, 5.0000
kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ,
50.00 MΩ, 500.0 MΩ |
|
| Capacitance |
| Accuracy |
1.0 % |
| Range and
Resolution |
1.000 nF,10.00 nF 100.0 nF,
1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF |
|
| Frequency |
| Accuracy |
0.005% + 5 |
| Range and
Resolution |
99.999 Hz, 999.99 Hz,
9.9999 kHz, 99.999 kHz, 999.99 kHz |
|
| Additional
functions/features |
| Multiple
on-screen displays |
Yes |
| True-rms
AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| Conductance |
50.00nS |
| Continuity
beeper |
Yes |
| Battery/Fuse
access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse
time clock |
Yes |
| Time of
day clock |
Yes |
| Min-Max-Avg |
Yes |
| Duty
Cycle |
0.01 % to 99.99 % |
| Pulse
Width |
0.025 ms, 0.25 ms, 2.5 ms,
1250.0 ms |
| Hold |
Yes |
| Isolated
Optical Interface |
Yes |
| Auto/Touch
Hold |
Yes |
| Reading
memory |
Yes |
| Log to PC |
Yes |
| Interval/Event
Logging |
Yes |
| Logging
Memory |
Up to 10,000 readings |
|
| Environmental
Specifications |
| Operating
Temperature |
|
| Storage
Temperature |
|
| Relative
Humidity |
|
0% to 90% (0 °C - 37 °C) |
|
0% to 65% (37 °C - 45 °C), |
|
0 to 45 % (45 °C - 55 °C |
|
| Electromagnetic
Compatability |
|
| Vibration |
|
Random vibration per
MIL-PRF-28800f Class 2 |
|
| Shock |
|
1 meter drop per IEC/EN
61010-1 2nd edition |
|
| Safety
Specifications |
| Overvoltage
category |
|
CAT III 1000 V / CAT IV
600 V safety rated |
|
| Agency
Approvals |
|
| Mechanical
& General Specifications |
| Maximum
voltage between any terminal and earth ground |
|
| Size |
|
(HxWxL 22.2 cm x 10.2 cm x
6 cm (8.75 in x 4.03 in x 2.38 in) |
|
| Weight |
|
| Battery
Life |
|
100 minimum, 200 hours in
logging mode |
|
| Battery
type |
|
6 AA alkaline batteries,
NEDA 15A IEC LR6 |
|
|