API Signal Conditioners

 




Price starts at $219.00

Product Code : API Signal Conditioners

Manufacturer : API

Models Available:

Add To Cart Email Friend Add To Saved Cart
DC Input Alarms
Download pdf with all products on this page
DC Input Alarm Trips
DC Input Alarm Trips with Transmitter

Click on model numbers below for data sheets and application information
LoopTracker® LED
Alarm Status LEDs
Push to Test/Reset Alarms
Lifetime Warranty
Reference Info
Alarm Terminology
Deadband
Relay Protection & EMI Suppression
Model Input Output Features
API 1000 G
DC Input Single Alarm Trip
Specify Input Range
Factory Configured
0-100 mVDC to
0-300 VDC
0-1 mADC to
0-900 mADC

With 5A Shunt Option
0-900 mADC to 0-5 ADC
One DPDT 7A Contact Set
Field Adjustable Setpoint
Specify Alarm Type
See data sheet for alarm options
  • Hot-Swappable Plug-In Design
  • Direct Replacement for Action AP 1000 and AP 1020
  • LoopTracker LED for Input
  • Alarm Status LEDs
  • Output Test Button
  • Uses API-011 11-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed
Api 1000G
API 1020 G
DC Input Dual Alarm Trip
Two SPDT 7A Contact Sets
Field Adjustable Setpoints
Specify Alarm Type
See data sheet for alarm options
API 1005 G
DC Input Single Alarm Trip
with Loop Power Supply
Factory Configured
4-20 mADC
One DPDT 7A Contact Set
Field Adjustable Setpoint
Specify Alarm Type
See data sheet for alarm options
  • Hot-Swappable Plug-In Design
  • LoopTracker LED for Input
  • Alarm Status LEDs
  • Output Test/Alarm Reset Button
  • 18 V Loop Power Supply
  • Uses API-011 11-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed
Api 1005G
API 1025 G
DC Input Dual Alarm Trip
with Loop Power Supply
Two SPDT 7A Contact Sets
Field Adjustable
Specify Alarm Type
See data sheet for alarm options
API 1040 G
DC Input Single Alarm Trip
with Non-Isolated DC-DC Transmitter and Loop Power Supply
Specify Input Range
Factory Configured
0-100 mVDC to
0-200 VDC
±100 mVDC to ±10 VDC
0-1 mADC to
0-50 mADC
One SPDT 7A Contact Set
Field Adjustable Setpoint
Specify Alarm Type
See data sheet for alarm options

Specify Transmitter Output Range
Factory Configured Output
0-1 V, 0-5 V, 1-5 V, 0-10 V,
±5 V, ±10 V,
0-20 mA, 4-20 mA
Others Available
  • Hot-Swappable Plug-In Design
  • LoopTracker LED
  • Alarm Status LEDs
  • Output Test/Alarm Reset Button
  • 18 V Loop Power Supply
  • Uses API-011 11-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed
Api 1040 G
API 1080 G
Field Selectable Minuteman Setup
DC Input Single Alarm Trip
with Loop Power Supply
24 Field Configurable Input Ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
Field Configurable Alarm
One DPDT 7A Contact Set
Adjustable Setpoint
  • Minuteman One-Minute Setup
  • Hot-Swappable Plug-In Design
  • LoopTracker LED
  • Alarm status LED
  • Output Test/Alarm Reset Button
  • 18 V Loop Power Supply
  • Uses API-011 11-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed
Api 1080 G
Socket Sold Separately
API 1080 DIN
Field Selectable Minuteman Setup
DC Input Single Alarm Trip
with Loop Power Supply
24 Field Configurable Input Ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
Field Configurable Alarm
One DPDT 7A Contact Set
Adjustable Setpoint
  • Minuteman One-Minute Setup
  • LoopTracker LED
  • Alarm status LED
  • Output Test/Alarm Reset Button
  • 12 V Loop Power Supply
  • DIN Rail or Surface Mount
  • 22.5 mm Wide
  • 80-265 VAC or 48-300 VDC Powered
  • API 1080 DD for 9-30 VDC Power (+$60)
Api 1080 DIN
API 1090 G
Field Selectable Minuteman Setup
DC Input Dual Alarm Trip
with Loop Power Supply
26 Field Configurable Input Ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
Field Configurable Alarms
Two SPDT 7A Contact Sets
Adjustable Setpoints
  • Minuteman One-Minute Setup
  • Hot-Swappable Plug-In Design
  • LoopTracker LED
  • Alarm status LEDs
  • Output Test/Alarm Reset Button
  • 18 V Loop Power Supply
  • Uses API-011 11-Pin Socket
  • 115 VAC Powered
  • A230 option for 230 VAC Power
  • D option for 9-30 VDC Power (+$60)
UL listed
Api 1090 G
Socket Sold Separately
API 1090 DIN
API 1090 DIN DD

Field Selectable Minuteman Setup
DC Input Dual Alarm Trip
24 Field Configurable Input Ranges
Min: 0-50 mVDC
Max: ±10 VDC
Min: 0-1 mADC
Max: 0-20 mADC
Field Configurable Alarms
Two SPDT 7A Contact Sets
Adjustable Setpoints
  • Minuteman One-Minute Setup
  • LoopTracker LED
  • Alarm status LEDs
  • Output Test/Alarm Reset Button
  • 12 V Loop Power Supply
  • DIN Rail or Surface Mount
  • 22.5 mm Wide
  • 80-265 VAC or 48-300 VDC Powered
  • API 1090 DD for 9-30 VDC Power (+$60)
Api 1090 DIN
 Recommended Items:
Page: 1 of 2 
$0.00
$8.00
$259.00
1 2
 