Building Diagnostic Thermal Imager

 




Price starts at $5,499.95

Product Code : FLK-TiR125 9 Hz

Manufacturer : Fluke

Add To Cart Email Friend Add To Saved Cart
  • Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
  • Always have references handy—IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
  • Find problems faster and easier—IR-Fusion®
  • Multi-mode video recording—focus-free video in visible light and infrared with IR-Fusion.
  • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).
Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti110 Industrial-Commercial Thermal Imager.

 

Model Name Description
FLK-TiR125 9 Hz Building Diagnostics Thermal Imager (9 Hz) Includes:
  • Thermal imager
  • AC power adapter
  • Lithium ion smart battery (2)
  • USB cable
  • SD memory card
  • Hard carrying case
  • Soft transport bag
  • Adjustable hand strap (left- or right-handed use)
  • Printed users’ manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD—total of 18
  • SmartView® software and warranty registration card
  • Two-bay charging base
  • Multi-format USB memory card reader

 

Detailed specifications

Building diagnostics

IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 µm to 14 µm (long wave)
Capture or refresh rate 9 Hz
NETD (tdermal sensitivity) ≤ 0.08 °C at 30 °C target temp (80 mK)
FOV (Field of view) 22.5 °H x 31 °V
IFOV (Spatial resolution) 3.39 mRad
Temperature measurement range (not calibrated below -10 °C) -20 °C to +150 °C (-4 °F to +302 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex™ focus system
IR-FusionR technology PIP, FULL IR, FULL VISIBLE, AutoBlend™
Color alarms High termperature, low temperature (dewpoint), and isotderm
Standard palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber
Ultra Contrast palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Metal, Ironbow, Amber, Inverted Amber
Hot/cold markers Yes
User definable spot markers Three on camera and in SmartView®
Centerbox (MIN/AVG/MAX) Yes
Level and span control Manual and auto
Minimum span in auto mode 2.5 °C
Minimum span in manual mode 2.0 °C
Minimum IR focus distance 15.25 cm (6 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade
Minimum parallax ~18-22 inches
IR-PhotoNotes annotation system Yes (3 images)
Laser pointer Yes
Torch Yes
Electronic (cardinal) compass Yes
Emissivity correction Yes
transmission correction Yes
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image
Multi-mode video output Streaming USB video output
Multi-mode video recording (standard AVI witd MPEG encoding) Yes (AVI witd MPEG encoding)
Multi-mode video recording (radiometric .IS3) Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon tdermal scene
Memory review tdumbnail review
Battery (field-replaceable, rechargeable) Two
Battery life 4+ hours (each)*
External battery charging base Included
Charging power supply Yes
Drop test 2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529) IP 54
Est. calibration cycle Two-years
Multifunction card reader Included
Memory storage 2 GB SD memory card
Direct download capability mini USB direct download
Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity Operating and storage 10 % to 95 %, non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick IEC/EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes

*Assumes 50% brightness of LCD

*Assumes 50% brightness of LCD
Extended warranty and service plans Yes
*Assumes 50% brightness of LCD
Extended warranty and service plans Yes

 

Batteries, Chargers and Adapters
FLK-TI-SBC3 Charging Base for Ti32, Ti29, Ti27, Ti125, Ti110, Ti100, TiR32, TiR29, TiR27, TiR125 and Ti110 Thermal Imagers.
FLK-TI-SBP3 Extra battery pack for Ti32, Ti29, Ti27, Ti125, Ti110, Ti100, TiR32, TiR29, TiR27, TiR125 and Ti110 Thermal Imagers.
TI-CAR CHARGER TI-CAR CHARGER