The AT-6000 series, available in two different kits, combines a receiver and powerful transmitter to locate energized and de-energized wires, breakers, and fuses. The AT-6000-R Receiver detects the signal in wires and cables using two methods: active tracing method (with the Transmitter) and passive tracing method (without the Transmitter). The AT-6000-T Transmitter works on Energized and De-energized circuits up to 600 V AC/DC in Category I through Category III electrical environments and features high signal, low signal, and loop modes.
Key Features:
- Traces wires in walls, ceilings, floors and corners
- Locates breakers and fuses
- Pinpoints shorts and opens
- High resolution 2.5″ TFT LCD color display
- Three Transmitter signal modes
- “High Signal” mode for normal circuits
- “Low Signal” mode for precision tracing in difficult areas
- “Loop” mode for closed loop de-energized circuits
- Four Receiver tracing modes
- “Quick Scan” mode allows for quick wire detection at a longer distance
- “Precision” mode precisely pinpoints wires or faults located behind walls, floors, or ceilings
- “Breaker Identification” mode facilitates quick and easy breaker locating
- “Non-Contact Voltage Detection” mode utilizes passive tracing without the Transmitter to verify if a wire is energized
- Two automatically selected frequency modes for reliable tracing on energized and de-energized circuits
- Comes with custom Amprobe hard carrying case, test leads, and accessories
- Compatible with optional Signal Clamp (CT-400) clamp-on attachment and TIC 410A Hot Stick attachment to extend your reach
Specifications:
AT-6000-R Receiver | AT-6000-T Transmitter | CT-400 Signal Clamp | |
Measurement Category | CAT III 600 V | CAT III 600 V | CAT IV 600 V, CAT III 1000 V |
Operating voltage | 0 to 600 V AC/DC | 0 to 600 V AC/DC | 0 to 1000 V AC |
Operating frequency | Energized: 6.25 kHz De-Energized: 32.768 kHz | Energized: 6.25 kHz De-Energized: 32.768 kHz | Wire tracing: 32.768 kHz AC current measurement: 45 Hz to 400 Hz |
Hazardous voltage detection | See NCV detection | > 30 V AC/DC | N/A |
Signal indications | Numeric, bar graph display and audible beep | LEDs and audible beep | N/A |
Response time | Tip Sensor (energized/de-energized): 500 MS NCV: 500 MS Battery voltage monitoring: 5 sec | Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec | Instantaneous |
Current output of signal (typical) | N/A | Energized circuit: HI mode: 60 mA RMS LO mode: 30 mA RMS De-energized circuit: HI mode: 130 mA RMS LO mode: 40 mA RMS Loop mode: 160 mA RMS | 1 mA/A for AC current measurement with multimeter |
Signal voltage output (nominal) | N/A | De-energized circuit: LOW: 29 V RMS, 120 Vp-p HIGH: 33V RMS, 140 Vp-p With CT-400: loop model: 31 V RMS, 120 Vp-p | De-energized circuit: 2.4 V RMS, 24 Vp-p |
Range detection (open air) | Tip sensor (Energized): Max distance via air: up to 20 ft (6.1 m) Pinpointing: approx. 1.97 in (5 cm) Tip sensor (De-energized): Max distance via air: up to 14.7 ft (4.5 m) Pinpointing: approx. 1.97 in (5 cm) NCV detection (40 to 400 Hz): Max. sensitivity: 90 V up to 6.56 ft (2 m) Min. sensitivity: 600 V up to 0.39 in (1 cm) | N/A | N/A |